Free Same or Next Day Shipping. Have Questions? Call or Text: 888-221-7839

Compare MRCOOL DIY OuttaSight Ceiling Cassette Models

The MRCOOL DIY Series OuttaSightTM Ceiling Cassette offers a low-profile heating and cooling option that doesn't require ductwork or wall space.

The OuttaSight Ceiling Cassaette product lines from MRCOOL, offers a discreet heating & cooling for any space.

Perfect for retro-fits or new construction, this new ceiling cassette will remain out of sight while delivering the efficient heating and cooling.

Plus, maintenance is a breeze with the remote controlled elevating filter panel. 

Ceiling cassettes are split HVAC systems with indoor and outdoor units. The indoor unit is on the ceiling, and a hidden conduit connects it to the outdoor unit. Ceiling cassettes require no ductwork, which makes them ideal for places like garages.

Compare MRCOOL DIY® OuttaSight Ceiling Cassette Models in the chart below. 

 

CASSETTE MODEL CONDENSER MODEL MULTI-ZONE
DIYCASSETTE09HP-230C25
(Multi-Zone Only)
MULTI-ZONE
DIYCASSETTE12HP-230C25
(Multi-Zone Only)
SINGLE/MULTI-ZONE
DIYCASSETTE18HP-230C25
DIY-18-HP-C-230C25
Power Supply
V~Hz, Ph
208/230~60, 1 208/230~60, 1 208/230~60, 1
Cooling Capacity (Range)
Btu/Hr
/ / 17000 (5300~17200)
Input
W
/ / 1360 (460~1615)
Current
A
/ / 6.15 (~/~)
EER2
Btu/Hr/W
/ / 12.5
SEER2
Btu/Hr/W
/ / 23
Heating Capacity (Range)
Btu/Hr
/ / 19000 (6100~21500)
Input
W
/ / 1768 (530~1900)
Current
A
/ / 7.68 (~/~)
COP
Btu/Hr/W
/ / 3.15
HSPF4
Btu/Hr/W
/ / 10.3
HSPF5
Btu/Hr/W
/ / 7.6
Heating at 17°F (-8°C) Rated Capacity
Btu/Hr
/ / 15100
COP
Btu/Hr/W
/ / 2.34
Heating at -4°F (-20°C) Rated Capacity
Btu/Hr
/ / 8600
Heating at -13°F (-25°C) Rated Capacity
Btu/Hr
/ / 6700
MINIMUM CIRCUIT AMPACTY (Indoor)
A
3 3 3
MAX. FUSE (Indoor)
A
5 5 5
Indoor Fan Motor
Model
ZKFN-30-8-43 ZKFN-30-8-43 ZKFN-30-8-43
Qty 1 1 1
RLA
A
1.54 1.54 1.54
Indoor air flow (SH/Hi/Mi/Lo)
CFM
335.3/315.9/287.1/205.9 364.7/329/264.7/205.9 400/351/260/207.06
Indoor noise level (SH/Hi/Mi/Lo)
dB(A)
42/40/35.5/24.5 43/41/35/26 44/40/28
Indoor unit Dimension (W*D*H)
inch
1278 x 335 x 228 1278 x 335 x 228 1278 x 335 x 228
Dimension (W*D*H)
inch
50.31 x 13.19 x 8.98 50.31 x 13.19 x 8.98 50.31 x 13.19 x 8.98
Packing (W*D*H)
mm
1463 x 571 x 575 1463 x 571 x 575 1463 x 571 x 575
Packing (W*D*H)
inch
57.60 x 22.48 x 22.64 57.60 x 22.48 x 22.64 57.60 x 22.48 x 22.64
Net/Gross weight
kg
20.1/39.9 20.1/39.9 20.6/40.3
Net/Gross weight
lb
44.31/87.96 44.31/87.96 45.2/88.854
Drainage water pipe diameter
mm
ODΦ25mm ODΦ25mm ODΦ25mm

 

Key Features

 Here are key features of the MRCOOL DIY OuttaSight Ceiling Cassette:

  • Low profile installation
  • Fits between 16" Ceiling Joists
  • Easy access filter
  • Multi and Single Zone Systems
  • Quiet Operation
  • Multiple operating modes
  • Advanced Filtration 

Room Size Chart based on sq ft of your space

What model should you get? We made this chart based on the square footage of your space and the recommended MRCOOL DIY® OuttaSightTM Ceiling Cassette model that will be powerful enough for cooling and heating in your space.

 

Space Size (Sq Ft) Recommended Model Cooling Capacity (Btu/Hr) Heating Capacity (Btu/Hr) Power Supply (V~Hz, Ph)
Up to 350 sq ft DIYCASSETTE09HP-230C25
(Multi-Zone Only)
9,000 / 208/230~60, 1
350–550 sq ft DIYCASSETTE12HP-230C25
(Multi-Zone Only)
12,000 / 208/230~60, 1
550–800 sq ft DIYCASSETTE18HP-230C25
DIY-18-HP-C-230C25
(Single/Multi-Zone)
17,000
(5300~17200)
19,000
(6100~21500)
208/230~60, 1

 

Multi-Zone Matchups for DIY OuttaSight Cassette

 

MRCOOL DIY Multi-Zone Condenser/Air Handler Matchups. 

Air handlers may be Ceiling Cassette or Wall Mounted. View the chart below on the number of units that can be matched with the condenser.

Model Number of Units Unit Matchups
DIY-MULTI2-18HP230C Two Units 9K + 9K
9K + 12K
12K + 12K
DIY-MULTI3-27HP230C Two Units 9K + 9K
9K + 12K
9K + 18K
12K + 12K
12K + 18K
18K + 18K
Three Units 9K + 9K + 9K
9K + 9K + 12K
9K + 9K + 18K
9K + 12K + 12K
9K + 12K + 18K
12K + 12K + 12K
12K + 12K + 18K
12K + 18K + 18K
DIY-MULTI4-36HP230C Two Units 9K + 9K
9K + 12K
9K + 18K
9K + 24K
12K + 12K
12K + 18K
12K + 24K
18K + 18K
Three Units 9K + 9K + 9K
9K + 9K + 12K
9K + 9K + 18K
9K + 12K + 12K
9K + 12K + 18K
9K + 18K + 18K
12K + 12K + 12K
12K + 12K + 18K
12K + 18K + 18K
12K + 12K + 24K
Four Units 9K + 9K + 9K + 9K
9K + 9K + 9K + 12K
9K + 9K + 12K + 12K
9K + 9K + 9K + 18K
9K + 12K + 12K + 12K
9K + 12K + 12K + 18K
9K + 9K + 12K + 18K
12K + 12K + 12K + 12K
12K + 12K + 12K + 18K
DIY-MULTI5-48HP230C Two Units 9K + 18K
9K + 24K
12K + 18K
12K + 24K
18K + 18K
18K + 24K
24K + 24K
18K + 36K
Three Units 9K + 9K + 9K
9K + 9K + 12K
9K + 9K + 18K
9K + 9K + 24K
9K + 12K + 12K
9K + 12K + 18K
9K + 12K + 24K
9K + 18K + 18K
12K + 12K + 12K
12K + 12K + 18K
12K + 12K + 24K
12K + 18K + 18K
Four Units 9K + 9K + 9K + 9K
9K + 9K + 9K + 12K
9K + 9K + 9K + 18K
9K + 9K + 9K + 24K
9K + 12K + 12K + 12K
9K + 12K + 12K + 18K
9K + 12K + 12K + 24K
9K + 9K + 12K + 18K
9K + 12K + 12K + 18K
Five Units 9K + 9K + 9K + 9K + 9K
9K + 9K + 9K + 9K + 12K
9K + 9K + 9K + 9K + 18K
9K + 9K + 9K + 9K + 24K
9K + 9K + 12K + 12K + 12K
9K + 9K + 12K + 12K + 18K
9K + 9K + 12K + 12K + 24K
9K + 12K + 12K + 12K + 18K

 

Resources: