Compare MRCOOL DIY OuttaSight Ceiling Cassette Models
The MRCOOL DIY Series OuttaSightTM Ceiling Cassette offers a low-profile heating and cooling option that doesn't require ductwork or wall space.
The OuttaSight Ceiling Cassaette product lines from MRCOOL, offers a discreet heating & cooling for any space.
Perfect for retro-fits or new construction, this new ceiling cassette will remain out of sight while delivering the efficient heating and cooling.
Plus, maintenance is a breeze with the remote controlled elevating filter panel.
Ceiling cassettes are split HVAC systems with indoor and outdoor units. The indoor unit is on the ceiling, and a hidden conduit connects it to the outdoor unit. Ceiling cassettes require no ductwork, which makes them ideal for places like garages.
Compare MRCOOL DIY® OuttaSight Ceiling Cassette Models in the chart below.
CASSETTE MODEL CONDENSER MODEL | MULTI-ZONE DIYCASSETTE09HP-230C25 (Multi-Zone Only) |
MULTI-ZONE DIYCASSETTE12HP-230C25 (Multi-Zone Only) |
SINGLE/MULTI-ZONE DIYCASSETTE18HP-230C25 DIY-18-HP-C-230C25 |
---|---|---|---|
Power Supply V~Hz, Ph |
208/230~60, 1 | 208/230~60, 1 | 208/230~60, 1 |
Cooling Capacity (Range) Btu/Hr |
/ | / | 17000 (5300~17200) |
Input W |
/ | / | 1360 (460~1615) |
Current A |
/ | / | 6.15 (~/~) |
EER2 Btu/Hr/W |
/ | / | 12.5 |
SEER2 Btu/Hr/W |
/ | / | 23 |
Heating Capacity (Range) Btu/Hr |
/ | / | 19000 (6100~21500) |
Input W |
/ | / | 1768 (530~1900) |
Current A |
/ | / | 7.68 (~/~) |
COP Btu/Hr/W |
/ | / | 3.15 |
HSPF4 Btu/Hr/W |
/ | / | 10.3 |
HSPF5 Btu/Hr/W |
/ | / | 7.6 |
Heating at 17°F (-8°C) Rated Capacity Btu/Hr |
/ | / | 15100 |
COP Btu/Hr/W |
/ | / | 2.34 |
Heating at -4°F (-20°C) Rated Capacity Btu/Hr |
/ | / | 8600 |
Heating at -13°F (-25°C) Rated Capacity Btu/Hr |
/ | / | 6700 |
MINIMUM CIRCUIT AMPACTY (Indoor) A |
3 | 3 | 3 |
MAX. FUSE (Indoor) A |
5 | 5 | 5 |
Indoor Fan Motor Model |
ZKFN-30-8-43 | ZKFN-30-8-43 | ZKFN-30-8-43 |
Qty | 1 | 1 | 1 |
RLA A |
1.54 | 1.54 | 1.54 |
Indoor air flow (SH/Hi/Mi/Lo) CFM |
335.3/315.9/287.1/205.9 | 364.7/329/264.7/205.9 | 400/351/260/207.06 |
Indoor noise level (SH/Hi/Mi/Lo) dB(A) |
42/40/35.5/24.5 | 43/41/35/26 | 44/40/28 |
Indoor unit Dimension (W*D*H) inch |
1278 x 335 x 228 | 1278 x 335 x 228 | 1278 x 335 x 228 |
Dimension (W*D*H) inch |
50.31 x 13.19 x 8.98 | 50.31 x 13.19 x 8.98 | 50.31 x 13.19 x 8.98 |
Packing (W*D*H) mm |
1463 x 571 x 575 | 1463 x 571 x 575 | 1463 x 571 x 575 |
Packing (W*D*H) inch |
57.60 x 22.48 x 22.64 | 57.60 x 22.48 x 22.64 | 57.60 x 22.48 x 22.64 |
Net/Gross weight kg |
20.1/39.9 | 20.1/39.9 | 20.6/40.3 |
Net/Gross weight lb |
44.31/87.96 | 44.31/87.96 | 45.2/88.854 |
Drainage water pipe diameter mm |
ODΦ25mm | ODΦ25mm | ODΦ25mm |
Key Features
Here are key features of the MRCOOL DIY OuttaSight Ceiling Cassette:
- Low profile installation
- Fits between 16" Ceiling Joists
- Easy access filter
- Multi and Single Zone Systems
- Quiet Operation
- Multiple operating modes
- Advanced Filtration
Room Size Chart based on sq ft of your space
What model should you get? We made this chart based on the square footage of your space and the recommended MRCOOL DIY® OuttaSightTM Ceiling Cassette model that will be powerful enough for cooling and heating in your space.
Space Size (Sq Ft) | Recommended Model | Cooling Capacity (Btu/Hr) | Heating Capacity (Btu/Hr) | Power Supply (V~Hz, Ph) |
---|---|---|---|---|
Up to 350 sq ft | DIYCASSETTE09HP-230C25 (Multi-Zone Only) |
9,000 | / | 208/230~60, 1 |
350–550 sq ft | DIYCASSETTE12HP-230C25 (Multi-Zone Only) |
12,000 | / | 208/230~60, 1 |
550–800 sq ft | DIYCASSETTE18HP-230C25 DIY-18-HP-C-230C25 (Single/Multi-Zone) |
17,000 (5300~17200) |
19,000 (6100~21500) |
208/230~60, 1 |
Multi-Zone Matchups for DIY OuttaSight Cassette
MRCOOL DIY Multi-Zone Condenser/Air Handler Matchups.
Air handlers may be Ceiling Cassette or Wall Mounted. View the chart below on the number of units that can be matched with the condenser.
Model | Number of Units | Unit Matchups |
---|---|---|
DIY-MULTI2-18HP230C | Two Units | 9K + 9K 9K + 12K 12K + 12K |
DIY-MULTI3-27HP230C | Two Units | 9K + 9K 9K + 12K 9K + 18K 12K + 12K 12K + 18K 18K + 18K |
Three Units | 9K + 9K + 9K 9K + 9K + 12K 9K + 9K + 18K 9K + 12K + 12K 9K + 12K + 18K 12K + 12K + 12K 12K + 12K + 18K 12K + 18K + 18K |
|
DIY-MULTI4-36HP230C | Two Units | 9K + 9K 9K + 12K 9K + 18K 9K + 24K 12K + 12K 12K + 18K 12K + 24K 18K + 18K |
Three Units | 9K + 9K + 9K 9K + 9K + 12K 9K + 9K + 18K 9K + 12K + 12K 9K + 12K + 18K 9K + 18K + 18K 12K + 12K + 12K 12K + 12K + 18K 12K + 18K + 18K 12K + 12K + 24K |
|
Four Units | 9K + 9K + 9K + 9K 9K + 9K + 9K + 12K 9K + 9K + 12K + 12K 9K + 9K + 9K + 18K 9K + 12K + 12K + 12K 9K + 12K + 12K + 18K 9K + 9K + 12K + 18K 12K + 12K + 12K + 12K 12K + 12K + 12K + 18K |
|
DIY-MULTI5-48HP230C | Two Units | 9K + 18K 9K + 24K 12K + 18K 12K + 24K 18K + 18K 18K + 24K 24K + 24K 18K + 36K |
Three Units | 9K + 9K + 9K 9K + 9K + 12K 9K + 9K + 18K 9K + 9K + 24K 9K + 12K + 12K 9K + 12K + 18K 9K + 12K + 24K 9K + 18K + 18K 12K + 12K + 12K 12K + 12K + 18K 12K + 12K + 24K 12K + 18K + 18K |
|
Four Units | 9K + 9K + 9K + 9K 9K + 9K + 9K + 12K 9K + 9K + 9K + 18K 9K + 9K + 9K + 24K 9K + 12K + 12K + 12K 9K + 12K + 12K + 18K 9K + 12K + 12K + 24K 9K + 9K + 12K + 18K 9K + 12K + 12K + 18K |
|
Five Units | 9K + 9K + 9K + 9K + 9K 9K + 9K + 9K + 9K + 12K 9K + 9K + 9K + 9K + 18K 9K + 9K + 9K + 9K + 24K 9K + 9K + 12K + 12K + 12K 9K + 9K + 12K + 12K + 18K 9K + 9K + 12K + 12K + 24K 9K + 12K + 12K + 12K + 18K |